W-D900 Smart Displacement Type Level Transmitter
\


Main technical parameters

Measuring range: 0.3m ~ 3m (special requirements optional)
Accuracy level: ± 0.5% FS
Output signal: DC two-wire system 4mA-20mA + digital signal (HART protocol)
Power supply voltage: 12V—36V DC
Nominal pressure: ≤16.0MPa / maximum 40MPa (optional)
Ambient temperature: -25 ℃ ~ + 55 ℃
Working temperature: -40 ~ + 250 ℃ (small heat sink)
           -40 ~ + 400 ℃ (large heat sink)
Specific gravity of the medium: 0.4g ~ 2.0g / cm3 (measured liquid level) ≥ 0.2 g / cm3 (measured density)
Specific gravity difference: ≥0.2g / cm3 (measurement interface)
Wetted material: displacer: 304 stainless steel
displacer cage and flange: Q235A carbon steel or 304 stainless steel
Transmitter housing: low-copper cast aluminum alloy, resin powder coating on the surface
Flange specifications::
DN Size Pressure(MPa) Flange type Flange standard
Side mounted connection flange DN20-DN50
Top mounted connection flange DN65-DN150
PN0.6~PN2.5 (RF) DIN,JIS,ASTM,etc.
PN4.0~PN10.0 (FM) DIN,JIS,ASTM,etc.
PN16.0 DIN,JIS,ASTM,etc.
Jacketed heating trace flange DN15 PN2.5 (RF) DIN,JIS,ASTM,etc.
Can also be manufactured according to user-supplied specifications and standards
Maximum load resistance: 600Ω (24V d.c) 
Display mode: -1.9.9.9.9.9. To 9.9.9.9.9. Physical quantity (LCD)
Outlet: M20х1.5 female thread) or 1 / 2NPT (optional)
Protection level: IP65
Explosion-proof grade: ExdⅡCT6