W-TFD360K Tuning Fork Densitometer
Main technical parameters
Measuring range |
0 – 2.5 g /cc (0 – 2500 kg/m3) |
Calibration range |
0 – 2.5 g /cc (0 – 2500 kg/m3) |
measurement accuracy |
± 0.002 g /cc (± 2 kg/m3) |
Repeatability |
± 0.0002 g /cc (± 0.2 kg/m3) |
Operating temperature range |
-50℃ ~ +150℃ |
Maximum working pressure |
16 bar (230 psi) |
Fluid viscosity range |
0 – 20000 cP |
Temperature Coefficient |
Less than 0.1 kg/m3/°C (after correction) |
Pressure effect |
Negligible |
Built-in temperature sensor |
Digital sensor |
Wetted material |
316L stainless steel Hastelloy |
Fork body coating |
Standard type, PTFE or electrolytic polishing |
Power supply |
24VDC, ≥50 mA |
Analog signal output |
4 -20 mA,0-1000Hz,RS485 Modbus RTU |
Output accuracy (20 ° C) |
± 0.1% of reading or ± 0.05% FS |
Output repeatability (-40 ~ +85 ° C) |
± 0.05% FS |
Process connection |
Clamped-on 50.5 |
Protection level |
IP65 |
Transmitter shell |
Aluminum alloy |